Home ProductsAuto Electric Water Pump

OWO INTERNATIONAL TRADING CO.,LTD

Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus

    • Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
    • Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
  • Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus

    Product Details:

    Place of Origin: China
    Brand Name: OWO
    Model Number: OWP-6000KL230T

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Payment Terms: L/C, T/T,L/C
    Contact Now
    Detailed Product Description
    Operate Voltage: DC 18V-32V Rated Flow:: 6000L/H
    Rated Head:: 7M Noise: ≤60dB
    Ip Grade: IP67 Service Life: ≥20000h
    Max Power: 230W

     

    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
     

    OWP-6000KL230T SERIES brushless DC water pump
    Boosting/circulation/Variable-frequency/Low-noise/centrifugal pump
    PWM control/Fault diagnosis
     
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
    ■ Applications
    Widely used in hybrid bus, hybrid passenger car, electric vehicles, trains, ships and other heating and cooling circulation system.
     
    ■ Features
    ◆Centrifugal pump
    ◆Magnetic force transmission
    ◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.
    ◆With wide range operating temperature
    ◆PWM signal speed controlling
    ◆Diagnostic signal output
    ◆With constant flow controlling
    ◆Reverse polarity protection
    ◆Dry running protection
    ◆Over Voltage, over current protection
    ◆Overload, over temperature protection
     
    ■ Technical description (related parts in contact with the liquid)
    Pump head housing: Die casting aluminum alloys
    Impeller: PPS+GF
    Shield cavity: PPS+GF
    Shaft sleeve: carborundum composite materials
    Shaft: stainless steel(3CR14) shaft
    Magnet housing: PPS plastic capsulation
    Seal ring: EPDM
     
    ■ Driving device (Including motor)
    Driving rotor: PPS plastic capsulated magnet
    Screws and nuts: SUS 304 stainless steel
    Driving Motor : brushless motor
    Motor wire frame :PPA GF
    Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..
     
    Bracket: steel
    Bracket hoop: US 304 stainless steel
    Waterproof based on IP67 rating (en60529)
    Connector model: AMP282106-1 (matched Plug AMP282088-1)
    Nozzle diameter:39.5mm (1.5 inch)
     
     
     
    Mounting instruction
    OWP-6000KL230T series pumps are centrifugal pumps which require pre-filled,
    The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .

    1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.
     
    2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.
     
    3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).
     
    4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .
     
    5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )
     
    6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).
     
    7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .
     
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
     
     
     
    ■ Temperature parameter
    Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
    Working ambient temperature: -40℃ to +120℃ (-40°F to +248°F)
    Storage temperature: -40℃ to +70℃ (-40°F to +158°F)
    (up to 100 ℃, but it will shorten the service life)
    System pressure
    -0.2 to 2.5 bar ( 100℃ (212°F).
    The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient temperature.
    Voltage range
    Rated 24V water pump, workable range 18V - 32V
    Although the motor can be used in a wide range of voltage and temperature, but excessive or too low voltage and temperature will affect the service life of the motor, the pump can not be exposed to thermal radiation ambient.
     
    Medium liquid: liquid mixture (Water with below 60% glycol)

     

    ■ Electrical parameter

    Working Voltage
    (VDC)

    Rated power
    (W)

    Rated flow
    (L/H)

    Dimensions
    (mm)

    Weight
    (g)

    18V-32V(24V) 230W Q=6000L/H, H=7m 193*90*159.5 2200g

     
     
     
     

     

     

    Connector model and the corresponding electrical properties (see figure 3):

    AMP282106-1 1( Black) 2( Yellow) 3(Blue) 4(Red)
    (matched Plug AMP282088-1) GND Fault feedback PWM +24V

     
     
     
     
     
     
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
     
     
    PWM character
     
     Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
     

    Duty Cycle Description

    Remark:
    1:PWM duty cycle metrical error ±2%
    2:PWM voltage:24VDC, frequency:1 KHz
    3: Recommended PWM stop duty cycle:7%
    4: Recommended 0% duty as PWM disconnect

    0%≤duty≤10% PWM mode (stop)
    11%≤duty≤55% PWM mode (Min speed)
    56%≤duty≤90% PWM mode (Linear speed control range)
    90%≤duty≤100% PWM mode (max speed limit)

     
     
    Attentions
    1. Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and engine during the installation, ensure the working environment temperature.
    2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the pump.
    4. Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
    5. Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
     
    Performance parameter
     
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
     

    External dimension
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus
    Heavy Duty High Flow Volume Auto Electric Water Pump Coolant Circulation For Electric Truck / Bus

    Contact Details
    OWO INTERNATIONAL TRADING CO.,LTD

    Contact Person: Amigo Deng

    Send your inquiry directly to us (0 / 3000)

    Contact

    Address: No.8 Tianshan road,Changzhou city,Jiangsu,China

    Factory Address:No.28 Shunyuan road,Changzhou city,Jiangsu,China & No.1199 Yunpin road,Jiading district,Shanghai,China